Fanuc System 10 and series 11 master board alarm code
Display: A.
Description: MDI Connection Failure.
Repair: Check fiber optic cable connection between control and MDI/CRT unit.
Display: C.
Description: MDI Failure.
Repair: Check the type (9”, 14”, etc.) of CRT/MDI unit or the edition number of NC software.
Connecting unit for operators panel or connecting cable is defective.
Display: F.
Description: Connection failure of connection unit or I/O cards D1-D3
Repair: Check fiber optic cable connections between units.
Replace Master PCB, Connection unit, I/O Board, Fiber Optic Cable
Failed I/O module in I/O base unit.
Display: H.
Description: Connection failure I/O.
Repair: Connection unit 2 or its connecting cable defective.
Display: c.
Description: Transfer error through fiber optic cable.
Repair: Check front panel power supply.
Replace Master PCB, MDI PCB, Connection unit PCB, I/O Unit, Fiber Optic cable.
Display: J.
Description: PC or interface converter not functioning.
Repair: Check PC-ROM cassette, PC Ram board, or interface convertor is mounted on Master PCB.
Display: L.
Description: Waiting for PC ready.
Repair: Replace PC ROM, PC ROM cassette or PC RAM Board.
Check PMC program.
Display: b.
Description: RAM check error.
Repair: Replace Master or ROM/RAM board.
Display 8.
Description: RAM check
Repair: Check power supply, Clear memory and reload parameters, Replace Master Board
Display: d.
Description: Power supply ready signal
Repair: Replace power supply, Master PCB
Display: E.
Description: System Error
Repair: Replace Master PCB , ROM PCB, or NC Software ROM
Wrong option parameters
No message on CRT – Clear Memory
Display: O.
Description: IPL MODE
Display: 1
Description: Normal Operation
Display: 4.
Description: Bad ACP
Repair: Replace ACP daughter board.
Display: Others
Description: System Error.
Repair: Replace master PCB, NC Software, ROM or ROM PCB